Back to Top

Hi, Guest!
Kelompok Produk X

Ceiling SuspendeD | N0N Inverter | InverteR | Daikin Air Conditioner Daikin Authorized Dealer | Daikin Parts Supplier | Daikin Authorized Service Center | Specialist AC Daikin | Mitsubishi | Haier : Split Wall Mounted - Ceiling Cassette - Ceiling Suspended - Split Duct - Floor Standing | VRV IV Daikin | VRF Mitsubishi | MR Terlengkap

BEST DEAL
Tipe Ceiling Suspended R-410A Upgrade ke sistem yang hening dan padat Menyebarkan udara yang nyaman ke seluruh ruangan Fleksibilitas pemasangan untuk kebebasan desain Operasi Hening Lebih mudah dipelihara Kisi yang tahan minyak Spesifikasi (R-410A) 13 18 21 26 Model Name Indoor Unit FHNQ13MV14 FHNQ18MV14 FHNQ21MV14 FHNQ26MV14 Outdoor Unit V14 RNQ13MV14 RNQ18MV14 RNQ21MV14 RNQ26MV14 Y14 - - - RNQ26MY14 Cooling Capacity*1,2 kW 3,8 5,3 6,2 7,6 Btu/h 13.000 18.000 21.000 26.000 Power Consumption Cooling*1 kW 1,58 2,04 2,38 2,65 COP W/W 2,4 2,6 2,6 2,87 Indoor Unit Sound Level (H/L) (220 V)*3 dB(A) 43/39 44/40 45/40 Dimensions (H x W x D) mm 195 x 960 x 680 195 x 1,160 x 680 195 x 1,400 x 680 Outdoor Unit Sound Level*4 Cooling dB(A) 49 51 52 54 Dimensions (H x W x D) mm 550 x 765 x 285 595 x 845 x 300 735 x 825 x 300 Piping Connections Liquid (flare) mm Ø 6,4 Ø 9,5 Gas (flare) mm Ø 12,7 Ø15,9 Drain Indoor Unit mm VP20(I.DØ20xO.DØ26) Outdoor Unit mm Ø18.0 (Hole) Max. Interunit piping lenght m 30 30 (equivalent length 50) Max. Installation level difference m 10 15 20 Heat insulation Both liquid and gas piping 30 36 42 48 Model Name Indoor Unit FHNQ30MV14 FHNQ36MV14 FHNQ42MV14 FHNQ48MV14 Outdoor Unit V14 - - - - Y14 RNQ30MY14 RNQ36MY14 RNQ42MY14 RNQ48MY14 Cooling Capacity*1,2 kW 8,8 10,4 12,3 14,1 Btu/h 30.000 35.000 42.000 48.000 Power Consumption Cooling*1 kW 3,07 3,64 4,51 5,51 COP W/W 2,87 2,86 2,73 2,56 Indoor Unit Sound Level (H/L) (220 V)*3 dB(A) 45/40 48/42 49/43 Dimensions (H x W x D) mm 195 x 1,400 x 680 195 x 1,590 x 680 Outdoor Unit Sound Level*4 Cooling dB(A) 55 54 56 58 Dimensions (H x W x D) mm 990 x 940 x 320 1,345 x 900 x 320 Piping Connections Liquid (flare) mm Ø 9,5 Gas (flare) mm Ø15,9 Drain Indoor Unit mm VP20(I.DØ20xO.DØ26) Outdoor Unit mm Ø26.0 (Hole) Max. Interunit piping lenght m 50 (equivalent length 70) Max. Installation level difference m 30 Heat insulation Both liquid and gas piping Note: *1Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal). *2Capacities are net, including a deduction for cooling for indoor fan motor heat. *3Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. *4In case of MV1: 220V, MY1: 380V.
  •     dari   1   halaman
  •